APPENDIX A: SIMULATION MODE (CONT.)
8. Check BREAD CRUMBS. Note the crumbs left as each car travels through.
Uncheck and the crumbs disappear.
9. Open drop box for FEET and METRIC and chose METRIC. Note all dimensions
have been changed to metric. If you save in metric and then go back to English
you may have rounding errors (e.g. 100 feet will become 99.99).
10. Note the clock. This is an hour meter for INTERSECTOR. Time is saved every 30
minutes. If you unplug before 30 minutes it resets to zero again. If you unplug at
31 minutes it will reset to 31 minutes.
11. To add a second zone use Zone 2 and enter 2 for OPTO OUTPUT. Enter 16 for X to
center this zone on one lane of cars. Click on SET ZONE DATA. Note zone 2 is
active and OPTO OUTPUT 2 is active. Click on SET ZONE DATA to store this text.
12. Typical set up for a zone would be to overlap side by side zones by 1 foot. Adjust
the WIDTH OF ZONE to get 1 foot overlap. The overlap is visible as darker area.
If a vehicle enters that area both Zones will be activated.
13. To copy data, click on STOP. The vehicles will stop on the display but moving
vehicles are still being tracked. Set ZONE SELECT to 3. Select ID to any vehicle
you would like to set a zone at. Note that the ID number is different from the
Vehicle number, which appears in the second column and in the chart. Note the X
and Y position of this ID and then click on COPY DATA. Those X and Y values are
now in the table. Set OPTO OUTPUT for zone 3 to 4. Click on START. Now you
have created a new zone that will activate OPTO OUTPUT 4. To take the unit back
to its initial settings, go to MAIN MENU, click on SETUP, then click on SET
DEFAULT VALUES. Upon returning to ZONE SETTING, all values should be back
to factory settings.
14. When finished, click on BACK, then on SETUP, then on SIMULATION MODE OFF.
INTERSECTOR
Microwave Motion and
Presence Sensor Installation Instructions
MS Sedco INTERSECTOR Installation Instructions Page Appendix A-2 INTERSECTOR-1.9Uv092717