4. Press and hold the pressure increase button 3 (Fig. 1), let the power uid pressure reach the
required manometer value 1 (Fig. 1), meanwhile, the caliper piston will move forward and reach
the stop (Fig. 5);
5. Leave this assembly connected for a while (about 30 seconds) and monitor the power uid
decrease indication. If the pressure does not change after the set time and there is no power uid
leak from the caliper, the unit works. Leak and pressure decrease on the manometer will signies
the caliper’s failure;
Fig. 5 – Caliper piston stop