18
The LVDS (Low Voltage Differential Signaling) connector provides a digital interface
typically used with flat panels. After connecting an LVDS interface flat panel to the
LVDS connector, be sure to check the panel datasheet and set the LVDS power
connector to the proper power voltage.
30
2
1
29
1 LCD_VDD 2 LCD_VDD
3 LCD_VDD 4 Ground
5 Ground 6 Ground
7 LVDSA_DATA0# 8 LVDSA_DATA0
9 LVDSA_DATA1# 10 LVDSA_DATA1
11 LVDSA_DATA2# 12 LVDSA_DATA2
13 Ground 14 Ground
15 LVDSA_CLK# 16 LVDSA_CLK
17 LVDSA_DATA3# 18 LVDSA_DATA3
19 LVDSB_DATA0# 20 LVDSB_DATA0
21 LVDSB_DATA1# 22 LVDSB_DATA1
23 LVDSB_DATA2# 24 LVDSB_DATA2
25 Ground 26 Ground
27 LVDSB_CLK# 28 LVDSB_CLK
29 LVDSB_DATA3# 30 LVDSB_DATA3
This connector is used to connect an on/ off switch for the backlight module of the
flat panel display.
1
1 L_BKLTEN# 2 L_BKLTCTL#
3
BKLT_VCC
4
BKLT_VCC
5 Ground 6 Ground
7 SEL_UP 8 SEL_DOWN