Temposonics
®
E-Series CANopen
Operation Manual
6
3.1 Order structure of E-Series EP
Temposonics
®
order code
a Sensor model
E P
Profile
b Design
0
Without position magnet
d Connection type
D 3 4
5 pin M12
f Output
C 3
0
4
CANopen
C 4
0
4
CANopen (duo terminator)
e Operating voltage
1
+24 VDC (−15 / +20 %)
Optional:
j Magnet number for multi position measurement
Z
0 2
2 magnets
i Type
1
Standard
h Resolution
4
10 µm
5
20 µm
g Baud rate
1
1000 kBit/s
2
500 kBit/s
3
250 kBit/s
4
125 kBit/s
c Stroke length
X X X X M
0050…2540 mm
X X X X
U
002.0…100.0 in.
Standard stroke length (mm)*
Stroke length Ordering steps
50 … 500 mm 25 mm
500…2540 mm 50 mm
Standard stroke length (in.)*
Stroke length Ordering steps
2 … 20 in. 1.0 in.
20…100 in. 2.0 in.
.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
E P
0 D 3 4
1
C
1
a b c d e
f
g h i
j
optional
3. Identification
*/ Non standard stroke lengths are available; must be encoded in 5 mm / 0.1 in. increments