3 Technical Data
3.1 Engine data 12V/16V2000Gx6S, 3B, continuous operation,
variable load, ICXN, optimized fuel consumption (provisional)
Legend
CP Ref. value: Continuous power. Continuous driving power under standard conditions
FSP Ref. value: Fuel stop power. Maximum engine power. In some applications, continuous power not pos-
sible (adjustment reserve)
A Design value. Value is required for configuration of an external system (plant)
R Guideline value. Typical average value for information; only conditionally suitable for configuration
L Limit value. Value that must not be undershot (lower limit, min. value) or exceeded (upper limit, max.
value); not suitable for configuration
N Value not yet defined. Value has not yet been, or will not be, named
- Not applicable. Module not relevant to this product type
X Applicable. Module relevant to this product type
> Actual value must be higher than specified value.
< Actual value must be lower than specified value.
* Value not sufficiently guaranteed (tolerance +/- 10%).
** Value not sufficiently guaranteed (tolerance +/- 5%).
ID Product type Application Engine speed Listed per-
formance
1 12V2000G16S Power generation
3B continuous opera-
tion, variable load,
ICXN
1800 rpm
60 Hz
716 kW
960 bhp
Ref. 25 °C/55 °C; Wa-
ter charge air cooling
(external)
Optimized fuel con-
sumption
2 12V2000G26S Power generation
3B continuous opera-
tion, variable load,
ICXN
1800 rpm
60 Hz
810 kW
1086 bhp
Ref. 25 °C/55 °C; Wa-
ter charge air cooling
(external)
Optimized fuel con-
sumption
3 12V2000G36S Power generation
3B continuous opera-
tion, variable load,
ICXN
1800 rpm
60 Hz
898 kW
1204 bhp
Ref. 25 °C/55 °C; Wa-
ter charge air cooling
(external)
Optimized fuel con-
sumption
4 16V2000G26S Power generation
3B continuous opera-
tion, variable load,
ICXN
1800 rpm
60 Hz
998 kW
1338 bhp
Ref. 25 °C/55 °C; Wa-
ter charge air cooling
(external)
Optimized fuel con-
sumption
Reference condition
ID 1 2 3 4
Intake air temperature °C 25 25 25 25
Charge air coolant temperature °C 55 55 55 55
Barometric pressure mbar 1000 1000 1000 1000
Site altitude above sea level M 100 100 100 100
22 | Technical Data | MS15054/00E 2015-09
TIM-ID: 0000065006 - 001