EasyManuals Logo

MTU 12V2000G series User Manual

MTU 12V2000G series
177 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #55 background imageLoading...
Page #55 background image
3.10 Engine data 12V/16V2000Gx6S, 3H, standby operation mode,
special qualifications, EPA Nonroad T2 (40CFR89) and EPA
Stationary EMERG T2 (40CFR60) (provisional)
Legend
CP Ref. value: Continuous power. Continuous driving power under standard conditions
FSP Ref. value: Fuel stop power. Maximum engine power. In some applications, continuous power not pos-
sible (adjustment reserve)
A Design value. Value is required for configuration of an external system (plant)
R Guideline value. Typical average value for information; only conditionally suitable for configuration
L Limit value. Value that must not be undershot (lower limit, min. value) or exceeded (upper limit, max.
value); not suitable for configuration
N Value not yet defined. Value has not yet been, or will not be, named
- Not applicable. Module not relevant to this product type
X Applicable. Module relevant to this product type
> Actual value must be higher than specified value.
< Actual value must be lower than specified value.
* Value not sufficiently guaranteed (tolerance +/- 10%).
** Value not sufficiently guaranteed (tolerance +/- 5%).
ID Product type Application Engine speed Listed per-
formance
1 12V2000G76S Power generation
3H standby operation
mode, special qualifi-
cations
1800 rpm
60 Hz
890 kW
1193 bhp
Ref. 25 °C/45 °C; Wa-
ter charge air cooling
(external)
EPA Nonroad T2 Comp
(40CFR89)
2 16V2000G76S Power generation
3H standby operation
mode, special qualifi-
cations
1800 rpm
60 Hz
1097 kW
1471 bhp
Ref. 25 °C/45 °C; Wa-
ter charge air cooling
(external)
EPA Stationary EMERG
T2 (40CFR60)
EPA Nonroad T2 Comp
(40CFR89)
3 16V2000G86S Power generation
3H standby operation
mode, special qualifi-
cations
1800 rpm
60 Hz
1371 kW
1837 bhp
Ref. 25 °C/45 °C; Wa-
ter charge air cooling
(external)
EPA Stationary EMERG
T2 (40CFR60)
EPA Nonroad T2 Comp
(40CFR89)
Reference condition
ID 1 2 3
Intake air temperature °C 25 25 25
Charge air coolant temperature °C 45 45 45
Barometric pressure mbar 1000 1000 1000
Site altitude above sea level m 100 100 100
MS15054/00E 2015-09 | Technical Data | 55
TIM-ID: 0000065016 - 001

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MTU 12V2000G series and is the answer not in the manual?

MTU 12V2000G series Specifications

General IconGeneral
BrandMTU
Model12V2000G series
CategoryEngine
LanguageEnglish

Related product manuals