EasyManua.ls Logo

MTU 12V2000M91 - Page 60

MTU 12V2000M91
169 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RL 211+A002-A040
Cause Corrective action
GMU 1 (PIM No. 21.X+A002-
A040) not detected on redundant
CAN bus.
1. Check LOP visually (→ Page 151).
2. Perform LOP test procedures (→ Page 153).
3. Contact Service.
Have GCU/GMU checked and replaced if required.
RL 211+A003-ECU
Cause Corrective action
ECU 4 not detected on redundant
CAN bus.
1. Check LOP visually (→ Page 151).
2. Perform LOP test procedures (→ Page 153).
3. Check ECU plug-in connections (→ Page 147).
4. Contact Service.
have ECU checked and replaced, if required.
RL 211+A004-EMU
Cause Corrective action
EMU 1 not detected on redundant
bus
1. Check LOP visually (→ Page 151).
2. Perform LOP test procedures (→ Page 153).
3. Contact Service.
have EMU checked and replaced, if required.
RL 211+A300-A500
Cause Corrective action
RCS with PIM No. 21.X+A300-
A500 not detected on redundant
CAN bus.
1. Check LOP visually (→ Page 151).
2. Perform LOP test procedures (→ Page 153).
3. Contact Service.
Have RCS checked and replaced, if required.
RL 211+A300-A501
Cause Corrective action
PCU (PIM No. 21.X+A30-A501)
not detected on redundant CAN
bus.
1. Check LOP visually (→ Page 151).
2. Perform LOP test procedures (→ Page 153).
3. Contact Service.
Have PCU checked and replaced, if required.
SS Safety System Failure (EMU)
Cause Corrective action
Safety system has detected fault
on Engine Monitoring Unit.
u Contact Service.
SS Power Reduction Active
Cause Corrective action
Safety system has requested
power reduction.
1. Determine cause of automatic power reduction.
2. Observe further display messages/alarms.
3. Contact Service.
60 | Troubleshooting | MW15409/04E 2015-08