602 – AL CAN Engine Start Lock
Yellow alarm; warning
Cause Corrective action
Start interlock initiated by plant. 1. Check plant configuration.
2. Restart engine (→ Page 36).
610 – AL Wiring HP Control Block 1
Yellow alarm; warning
Cause Corrective action
Wire break or short circuit at PWM
channel HP fuel control block.
u Check wiring or HP fuel control block, replace as necessary .
611 – AL Wiring HP Control Block 2
Yellow alarm; warning
Cause Corrective action
Fuel prefilter differential pressure
too high.
u Check wiring or HP fuel control block, replace as necessary.
615 – AL EIL Protection
Yellow alarm; emergency stop (15 min. delay)
Cause Corrective action
Alarm for Protection module as
reaction to faulty or manipulated
EIL.
u Replace EIL.
616 – AL EIL Error
Yellow alarm; warning
Cause Corrective action
Alarm with faulty or manipulated
EIL.
u Replace EIL.
762 – AL Smart Connect Lost
Yellow alarm; warning
Cause Corrective action
Smart Connect device has failed
on CAN bus.
u Check wiring or Smart Connect, replace as necessary.
832 – AL EIL Engine Number Differs
Yellow alarm; warning
Cause Corrective action
Alarm when fault numbers differ
between ECU and EIL.
u Contact Service.
MS150094/02E 2015-05 | Troubleshooting | 71