AV 14DA

DC AMPERE METER
AV-14DA
AV-24DA
AV-34DA
96 X 96mm
72 X 72mm
OPERATING MANUAL
AV-14DA,24DA,34DA
Technical Specification
1 TO 9999
Power Supply
Protection Level
Operating
Relative
(As per request)
Temperature
Humidity
230V AC, 50 Hz, Approx 4VA
IP-65(Front side) AS per IS/IEC 60529:2001
0°C To 55°C
Up to 95% RH Non Condensing
Model
Display
Size(HXWXD)
Panel Cutout
Input
Range
AV 14DA
96 X 96 X 50 mm
68 X 68 mm
92 X 92 mm
44 X 92 mm
72 X 72 X 85 mm
48 X 96 X 55 mm
4 Digit, Single Display
AV 24DA AV 34DA
75mV DC
AV 24DA

AV 34DA
48 X 96mm

NOTE : Every Time, When Instrument is turned on following parameter will be displayed.
(POWER ON)
(Process Value)



(Previously selected High range
value Display for 2 Second)
www.multispanindia.com
Page - 1
AV-14DA/24DA/34DA
Question and Answer IconNeed help?

Do you have a question about the MULTISPAN AV-14DA and is the answer not in the manual?

MULTISPAN AV-14DA Specifications

General IconGeneral
BrandMULTISPAN
ModelAV-14DA
CategoryMeasuring Instruments
LanguageEnglish

Summary

Technical Specification

Display

Details the display type for each model.

Size

Specifies the physical dimensions (H x W x D) of the meters.

Panel Cutout

Provides panel cutout dimensions required for installation.

Input

Specifies the electrical input requirements for the ampere meter.

Range

Indicates the measurement range of the ampere meter.

Power Supply

Details the power supply specifications.

Protection Level

Specifies the protection level of the instrument as per standards.

Operating Temperature

Defines the acceptable operating temperature range.

Relative Humidity

Specifies the acceptable relative humidity range.

Procedure for Range Selection

Initial Setup

Describes the initial power-on state and display.

Parameter Setting

Procedure to enter password for parameter settings.

Decimal Point Configuration

Steps for setting the decimal point.

High Range Selection

Procedure for setting the high range value.

Save and Exit

Procedure to save the configured settings and exit.

Connection Diagram

AV-14DA Connection

Illustrates the wiring and terminal connections for the AV-14DA model.

AV-24DA Connection

Illustrates the wiring and terminal connections for the AV-24DA model.

AV-34DA Connection

Illustrates the wiring and terminal connections for the AV-34DA model.

Safety and Installation Guidelines

General Safety Precautions

Instructions to ensure safety of personnel and the instrument.

Wiring Safety

Guidelines for safe wiring arrangements and connections.

Installation Guidance

Procedures and precautions for installing the instrument.

Mechanical Installation Details

Information on panel cutouts and terminal wiring.

Maintenance Instructions

Guidance on cleaning and upkeep of the equipment.