M1 CALL 123
* *
PSG/10433/1
RPR 550IS Series
TM1188 Issue 1Page 2 - 6
Figure 3: Display Representation of Call
New Status
11. Each call is automatically given new status when first received. New status is removed
by cancelling the alert or reviewing the call from memory. If the alert is left uncancelled
then `
x new messages
' appears on the display showing the number of messages with
new status (x corresponds from 1 to 5). The message must be viewed in full for the new
status to be removed.
Cancelling Alerts
12. Cancel the alert by pressing the Cancel button. The beep, LED and vibrate cease but
the message is replayed from the beginning.
Escalating Alert
13. The escalating alert has three stages - the first two lasting 4s each and the last one 8s,
16s, 32s or continuous. The stages are as follows:
Stage 1: LED, flashing beep pattern and vibrate (if fitted).
Stage 2: LED, low volume beep pattern and vibrate (if fitted)
Stage 3: LED, full volume beep pattern and vibrate (if fitted).
14. The entry point of the sequence, which can be stage 1, 2 or 3, is programmed into the
EEPROM. However, the escalating alert and the Mute mode are overridden by beep
code 5 (triple pip) and beep code 8 (continuous pip). They cause the alert to be on full
volume for the whole of the programmed alert duration.