Language: English (EN) - Original operating manual
Order number: C250-P-WO-0001515.6-EN-ER
Instruction manual
Chamber machine C250
MC06
Serial number:
.........................................................
Service address: Manufacturer:
MULTIVAC
Sepp Haggenmüller GmbH & Co. KG
Bahnhofstraße 4
D-87787 Wolfertschwenden, Germany
Tel.: 0049 8334 601 0
www.multivac.com
Date: 10.06.2014
The reproduction, distribution and utilization of this document as well as the communication of its contents to others without express authorization is
prohibited. Offenders will be held liable for the payment of damages. All rights reserved in the event of the grant of a patent, utility model or design.

Table of Contents

Questions and Answers

  • A
    abigail19Aug 17, 2025
    Why is my multivac Laboratory Equipment machine very loud?
    • M
      Mr. Kevin BurtonAug 17, 2025
      If your Multivac laboratory equipment is making excessive noise, it could be due to a clogged air de-oiling element, which requires replacement. Alternatively, the vacuum pump may be defective, in which case you should notify the service.
  • G
    Gary SanchezAug 20, 2025
    What to do if multivac Laboratory Equipment machine does not run?
    • J
      jason22Aug 20, 2025
      If your Multivac laboratory equipment isn't starting, first ensure that the machine is switched on. Also, check if the mains plug is properly plugged in. Lastly, ensure the ambient temperature is within the permissible range as specified in the Technical Specifications.
  • C
    christopher26Aug 22, 2025
    Why is the seal seam uneven and wavy on my multivac C250 Laboratory Equipment?
    • H
      hernandezstevenAug 22, 2025
      An uneven and wavy seal seam on your Multivac laboratory equipment often results from an insufficient pressure difference between the chamber and the outside environment during sealing. To resolve this, reduce the Evacuation pressure value, Gas flushing pressure value, and Gas flushing time value. Also, check if the sealing bar is damaged and replace it if necessary.
  • M
    mannhenryAug 26, 2025
    What to do if oil leaks out of multivac C250 Laboratory Equipment machine?
    • S
      susan74Aug 26, 2025
      If oil is leaking from your Multivac laboratory equipment, check whether the screw plugs or oil sight glass are not tight and tighten them. If the problem persists, the vacuum pump may be defective, and you should notify the service.
  • M
    Melissa WagnerAug 28, 2025
    Why is there odour or smoke coming from my multivac C250?
    • S
      scottmorenoAug 28, 2025
      If you notice an odor or smoke coming from your Multivac laboratory equipment, the air de-oiling element may be defective and needs to be changed. Alternatively, the oil return valve of the vacuum pump may be clogged, which requires you to notify the service.
  • B
    Breanna CalhounAug 31, 2025
    How to fix poor vacuum in the pack with multivac Laboratory Equipment?
    • D
      davisstephanieAug 31, 2025
      If you're experiencing a poor vacuum in the pack with your Multivac laboratory equipment, it may be due to the evacuation pressure being set too high. Try reducing the evacuation pressure value to improve the vacuum.
  • K
    Kathy MullenSep 3, 2025
    Why is there high oil consumption in my multivac C250?
    • K
      Kimberly AllenSep 3, 2025
      High oil consumption in your Multivac laboratory equipment is often due to a clogged air de-oiling element. Consider changing the air de-oiling element.
  • J
    Johnathan BakerSep 5, 2025
    What to do if chamber lid does not remain closed despite pump running on multivac C250 Laboratory Equipment?
    • A
      adam60Sep 5, 2025
      If the chamber lid on your Multivac laboratory equipment doesn't stay closed while the pump is running, ensure you press the chamber lid shut more evenly, firmly, and for a longer duration. Also, check if the chamber lid gasket is dirty and clean it. If the issue continues, the chamber lid gasket may be damaged and needs to be changed.
  • C
    Christopher JonesSep 8, 2025
    What to do if the excess pouch neck can only be severed with difficulty at the sever seal or it can not be severed at all on multivac Laboratory Equipment?
    • K
      kjonesSep 8, 2025
      If you're having trouble severing the excess pouch neck on your Multivac laboratory equipment, the sealing time may be set incorrectly. Increase the value for sealing time in small increments.
  • M
    Melanie ParksSep 12, 2025
    Why is seal seam milky on multivac C250?
    • C
      Carlos ClementsSep 12, 2025
      A milky seal seam on your Multivac laboratory equipment indicates that the sealing time is set incorrectly. Reduce the sealing time value until the seal seam becomes clear and transparent.

Summary

Safety

General Safety Instructions

Provides fundamental safety guidelines for machine operation and personnel.

Unauthorized Modifications and Spare Parts

Warns against using non-genuine parts and performing unauthorized modifications.

Obligations of the Operating Company

Details operator responsibilities for safety, personnel, and operations.

Start-up Procedures

Connecting Power and Gas Supply

Instructions for connecting the machine to power and inert gas.

Machine Operation

Machine Power and Basic Operations

Details switching the machine on and off, including self-tests.

Product Packing and Process Setup

Guides on packing products, using recipes, and setting up processes.

Adjustment Work and Setup

Cleaning Procedures

Machine Cleaning Steps (Daily and Intensive)

Details procedures for daily and intensive cleaning, including component handling.

Machine Maintenance

Maintenance Schedule Overview

Presents a schedule of required maintenance tasks based on frequency.

Detailed Maintenance Recommendations

Provides specific guidance for visual inspections, tests, and checks.

Specific Maintenance Tasks

Covers vacuum testing, sealing bar replacement, and oil changes.

Troubleshooting Guide

Malfunctions with Diagnostic Messages

Lists common malfunctions with diagnostic codes and their solutions.

Faults Without Diagnostic Messages

Details common faults without codes and their troubleshooting steps.

Shutdown, Transport, and Storage

Disposal Procedures

Spare Parts Information

multivac C250 Specifications

General IconGeneral
Brandmultivac
ModelC250
CategoryLaboratory Equipment