Description
Preset recipes
34 10.06.2014
Recipe Example of
use
Evacuation
pressure
Automatic
sensitivity
Gas flush-
ing pres-
sure
Sealing
time
MHP
No. 3 For dry
products
with little
gas flush-
ing.
Automatic 4 100 mbar to
150 mbar
1.8 s Off
No. 4 For dry
products
with me-
dium gas
flushing.
Automatic 4 250 mbar 1.8 s Off
No. 5 For dry
products
with strong
gas flush-
ing.
Automatic 4 500 mbar 1.8 s Off
No. 6 For prod-
ucts with a
big air
pocket.
12 mbar 10 Off 1.8 s Evacuation
time: 2 s
Evacuation
pause: 4 s
No. 30 Factory
settings
10 mbar 6 Off 1.3 s Evacuation
time: 2 s
Evacuation
pause: 2 s
2.8 Technical data
Power supply connection
Mains voltage See type plate.
Phases See type plate.
Nominal power See type plate.
Nominal current See type plate.
Maximum pre-fuse See type plate.
Max. short-circuit current See type plate.
Protection type IP54
Dimensions
Height (a) with open chamber lid 730 mm