Maintenance
Maintenance recommendation
10.06.2014 69
¾ If necessary, replace the sealing bar, see Section 7.4 "RE-
PLACE THE SEALING BAR".
¾ Check the counter-pressure bar for damage.
¾ If necessary, repair the counter-pressure bar,.
7.2.4 Entire machine - Alkaline cleaning and disinfection
¾ See company cleaning guidelines and.
7.2.5 Vacuum pump - Checking oil level, topping up
¾ Check the oil level on the oil sight glass.
¾ If water is present in the oil, change the oil in the vacuum
pump, see Section 7.5 "CHANGE THE OIL IN THE VACUUM PUMP".
¾ If necessary, refill oil,.
7.2.6 Entire machine - Acidic cleaning and disinfection
¾ See company cleaning guidelines and.
7.2.7 Connections - Visual inspection
¾ Disconnect the machine from the mains electricity.
¾ Check power cable for damage.
¾ If present, check that the supply line for inert gas is fitted tightly
and undamaged.
7.2.8 Vacuum system - Check
¾ Perform a vacuum test, see Section 7.3 "PERFORMING THE VAC-
UUM TEST".
7.2.9 Vacuum pump - Oil change
¾ Change the oil in the vacuum pump, see Section 7.5 "CHANGE THE
OIL IN THE VACUUM PUMP".
7.2.10 Vacuum pump - Exchanging the air de-oiling ele-
ment
¾ Change the air de-oiling element,.