Cleaning
Cleaning the machine
64 10.06.2014
¾ Insert the dry chamber lid gasket in the groove of the lid.
¾ If the chamber lid gasket or groove is wet, dry with a new cloth
or sterile compressed air.
Info
During insertion, do not stretch the gasket.
¾ Smooth out gasket.
¾ Disinfect gasket with alcohol-based disinfectant.
¾ Switch on the machine.
¾ Close and press down the chamber lid and observe the pressure
shown in the display.
The pressure drops: the chamber is airtight.
The pressure does not drop: the chamber is not airtight.
¾ If the chamber is not airtight, check the chamber lid gasket:
¾ Smooth out gasket.