2202MYJE-MY-C8-N_2018.02.
Compound 2-stage Screw Compressor
3225 * * C Instruction Manual
3225LLLC/3225LLMC/3225LLSC/3225LLC/3225LMC/3225LSC
3225MLC/3225MMC/3225MSC/3225SLC/3225SMC/3225SSC
CAUTION
Before operating, servicing, or inspecting this product, read this manual thoroughly to fully
understand the contents.
Keep this Instruction Manual in a safe, designated place for future reference whenever the
manual is needed.
Specifications of this product and contents of this manual are subject to change without
prior notice due to technical improvements, and the like.

Table of Contents

Questions and Answers

  • I
    ian48Aug 18, 2025
    Why does my mycom 3225**C stop immediately after startup?
    • M
      Mrs. Donna Hood MDAug 18, 2025
      If your mycom Compressor stops immediately after starting, it could be due to insufficient refrigerant flow (check for leaks, stop them, and add refrigerant) or insufficient liquid supply (inspect the expansion valve and liquid supply strainer). Another cause could be heat exchange failure in the heat exchanger, so investigate the cause and take necessary actions. Lastly, the failure of a low pressure protection device, pressure sensor, or relay could be the reason, so identify and replace any defective devices.
  • M
    Mrs. Andrea CostaNov 3, 2025
    How to troubleshoot a mycom 3225**C Compressor that does not start up?
    • W
      williamsamandaNov 3, 2025
      If the mycom Compressor does not start, several factors could be at play. It might be due to the power source being off, so you should use a check sheet for post-inspection actions. The main motor could have failed, so refer to the motor's operation manual for troubleshooting. The micro-switch might not be sensing capacity control, in which case you should replace it. Other potential causes include a defective capacity control oil supply line (readjust), leaks or clogs in piping or the solenoid valve (remove cause and check/replace oil), or a clogged pressure pipe (remove clogging and check/replace oil). Also check for oil pressure, cooling water circulation, clogs in the circulation route (remove the clogging), or issues with the compressor startup circuit (replace faulty components). Fin...
  • C
    Christopher CookNov 9, 2025
    What to do if the mycom 3225**C Compressor has low oil pressure?
    • B
      Bruce DaviesNov 9, 2025
      If your mycom Compressor's oil pressure is low, it could be due to several reasons. The oil filter element might be clogged, so remove the clogging and check/replace the oil. There may be internal defects, so check for oil contamination and conduct vibration/noise diagnosis, overhauling the compressor if necessary. Other possible causes include insufficient oil in the oil separator (inspect the oil heater and relays), insufficient oil return due to refrigerant circulation issues (correct refrigerant circulation and return oil from the load-side heat exchanger), or clogs in the oil return passage (remove the causes and restore the system). Also, check for extensive oil leaks and address them and ensure the oil pressure detection function is working correctly by identifying and replacing any...
  • M
    Megan VasquezNov 25, 2025
    What causes unusually high pressure in a mycom 3225**C Compressor?
    • A
      anthonyjohnsonNov 25, 2025
      If the pressure in your mycom Compressor is unusually high, it could stem from several issues. Heat exchange failure in the condenser might be the cause, so clean and wash it, possibly using chemical cleaning. Another potential cause is failure in the fan motor, thermo switch, water spraying pipes, or cooling water pumps, so identify and replace any defective devices. Faulty adjustment of cooling water or brine could also be to blame, so readjust the valve or investigate the cause if using an automatic control valve. Other causes of insufficient cooling water flow should be investigated, such as clogged filters, leaks in circulation routes, or frozen water supply routes. Deficiency in heat exchanger performance may also be a factor, so re-examine operating conditions or improve the install...

Summary

Warranty and Disclaimer

Important Information

For Safe Use of This Product

Provides crucial safety guidelines and precautions for operating the compressor.

Chapter 1 Safety

Strict Requirements and Prohibitions

Lists essential 'do's' and 'don'ts' for safe operation and maintenance.

Safety Devices

Describes essential safety features and their functions.

Chapter 2 Compressor Specifications and Structure

Compressor Specifications

Lists technical specifications like product mass, swept volume, and pipe sizes.

Mechanisms

Explains the working principles of screw compression and related systems.

Chapter 3 Installation

Chapter 4 Compressor and Package Unit Operation

Lubricating Oil (Refrigerant Oil)

Provides guidelines on selecting, managing, and changing lubricating oil.

Chapter 5 Maintenance and Inspection

Precautions for Maintenance and Inspection

Outlines critical safety measures and general guidelines for maintenance tasks.

Disassembly and Inspection

Provides step-by-step procedures for disassembling and inspecting compressor components.

Reassembly

Details the procedures for reassembling the compressor after maintenance.

Chapter 6 Troubleshooting

Compressor does not start up

Identifies causes and actions for compressor startup failures.

Compressor stops immediately after startup

Addresses issues causing immediate shutdown after starting.

mycom 3225**C Series Specifications

General IconGeneral
Brandmycom
Model3225**C Series
CategoryCompressor
LanguageEnglish