100 Mb Fiber Transceiver Characteristics
Fiber Length
2km* 15km** 40km** 80km**
TX Power Min
-19dBm -15dBm -5dBm -5dBm
RX Sensitivity Max
-31dBm -31dBm -34dBm -34dBm
Wavelength Min/Max
1310nm 1310nm 1310nm 1550nm
* Multimode Fiber Optic Cable
** Singlemode Fiber Optic Cable
Regulatory Approvals:
Safety: Suitable for use in Class I, Division 2, Groups A, B, C and D Hazardous Locations, or
Nonhazardous Locations only.
EMI: ANSI C63.4
FCC 47 CFR Part 15, Subpart B - Class A
ICES-003 – Class A
EMC: EN 61000-6-2 (Immunity)
EN 61000-6-4 (Emissions)
IEC 61000-4-2 (ESD)
IEC 61000-4-3 (RFI)
IEC 61000-4-4 (EFT)
IEC 61000-4-5 (Surge)
IEC 61000-4-6 (RF)
IEC 61000-4-8 (PF)
IEC 61000-4-11 (Voltage Dips)

Table of Contents