- Allow the product to cool down for at least 30 minutes or until error is no
longer displayed.
- We recommend allowing product to cool for at least 1 minute between cycles.
- Do not use the product continuously for more than 10 cycles.
05. DISPLAY SHOWS ‘ERROR BLEND’ OR ‘ERROR SPIN
ERROR BLEND” – During the blending cycle, if the unit is unable to regulate
the speed correctly, a safety will trigger and automatically stop the unit, and the
“ERROR BLEND” message will appear on the display. Make sure ingredients are
not lled above the maximum ll line. If the problem persists, please contact
Nama Customer Service.
ERROR SPIN” – During the spinning cycle, if the unit is unable to regulate the speed
correctly a safety will trigger and automatically stop the unit, and the “ERROR SPIN
message will appear on the display. Make sure ingredients are not lled above the
maximum ll line. If the problem persists, please contact Nama Customer Service.
06. THE PRODUCT IS VIBRATING DURING OPERATION.
It is normal for the product to wobble slightly due to the vibrations produced by the
base and chamber set. Excessive vibrations can be caused by overloading or damaged
parts, please refer to table below:
21
Issue Observation Recommendation
Overloading Ingredient level exceeds
the Max Fill Level
Reduce the amount of ingredients so
that the total volume does not exceed
the Max Fill Line
Ratio of liquids to solids
too low
Increase liquids when blending to
promote improved ingredient circulation
Part Damage Blade Frame Inspect the blade frame for any damage.
If found, contact Nama Customer Service.
Filter Basket Inspect the lter for any damage. If found,
contact Nama Customer Service.
Lid Hub Assembly Inspect the lid hub assembly that receives
the blade frame pin for any signs of
damage, wear or tear. If found, contact
Nama Customer Service.
Drive Couplings Inspect the base and chamber metal drive
couplings for damage. If found, contact
Nama Customer Service.