NANO NDL-100 - User Manual

Default Icon
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
User guide
heatless desiccant air dryer
revision: 2022-116 document: 17-100-0120
© 2022 Air & Gas Solutions LLC.
www.n-psi.co.uk

Other manuals for NANO NDL-100

Questions and Answers

  • S
    Sheri WeaverAug 9, 2025
    What to do if my NANO NDL-100 Dehumidifier is not cycling?
    • K
      kristenchavezAug 9, 2025
      If your NANO Dehumidifier isn't cycling, first ensure the controller is powered and check the on-screen column status to confirm it's powering the solenoid valves during normal operation. Also, check the power to the unit and the fuse (T2A 250V) located at Fig 8.A. Insufficient inlet pressure could also be the culprit; ensure it's at least 4 barg and adjust the inlet pressure settings if needed. A failure to de-pressurize during cycling could indicate a solenoid valve malfunction. If the coil has power, replace the valve. A working valve should produce an audible click when energized. Finally, check the inlet air supply if the outlet flow stops.
  • C
    christensenbrianAug 19, 2025
    Why does my NANO NDL-100 Dehumidifier have poor dew point performance?
    • S
      scottkimAug 19, 2025
      If your NANO Dehumidifier shows poor dew point performance, start by checking the inlet pressure; it should be a minimum of 4 barg. Adjust the inlet pressure settings if necessary. Ensure the power is on, the dryer front panel is illuminated, and the dryer is cycling correctly. If the desiccant is moist or contaminated, identify and eliminate the source of contamination and replace the cartridges, avoiding reuse. Confirm that the dryer's performance matches the required system air consumption. Verify the inlet air temperature against the technical specifications. Insufficient purge air can also cause this issue; consult service personnel to adjust the settings, as they are factory pre-set. Lastly, a blocked exhaust silencer may be the cause, requiring assistance from service personnel.
  • J
    Jeffrey CalderonAug 29, 2025
    What to do if my NANO NDL-100 has constant depressurization?
    • B
      brent26Aug 29, 2025
      If your NANO Dehumidifier is constantly depressurizing, try switching it off and restarting it. Make sure the dryer is pressurized before powering it on to allow it to initialize before starting operation. Erratic airflow from the exhaust may indicate a faulty or damaged valve, requiring service.

Summary

General Information

Document and Safety Guidelines

General Safety

Warns against modifications, stresses compliance with safety regulations, and requires authorized personnel.

Technical Specifications

System Layout and Site Location

Typical System Layout

Illustrates system diagram with inlet filtration, bypass options, and compressed air flow.

Operation Procedures

Startup and Safety

Details startup steps, safety (grounding), LEDs, and display panel functions.

Remote Control Functions

Remote Start;Stop Control

Explains access and setup for remote start/stop using specific wires.

Remote Stop Control

Describes implementing remote stop via connector pins and its operational effect.

Shutdown Procedure

Isolation and Depressurization

Outlines shutdown steps, emphasizing isolation from air/electrical and proper depressurization.

Monitoring Dryer Performance

Maintenance

Maintenance Precautions

Essential precautions: system shutdown, isolation, approved parts, seal checks.

Service Schedule

Scheduled Maintenance Tasks

Presents a service schedule table for maintenance tasks at yearly intervals.

Troubleshooting

Process and Instrumentation Diagram

Wiring Diagram

NANO NDL-100 Specifications