User guide
D3 heatless desiccant air dryer
revision: 2022-214 document: 17-100-0690
© 2022 Air & Gas Solutions LLC
www.n-psi.co.uk

Other manuals for NANO NDL-2130

Questions and Answers

  • R
    robinsonkatieAug 10, 2025
    What to do if my NANO NDL-2130 fails to cycle?
    • S
      Scott GeorgeAug 10, 2025
      If your NANO Dehumidifier fails to cycle, there are several potential causes. First, ensure the controller is powered and check the on-screen column status to confirm it's powering the solenoid valves during normal operation. Also, verify the power to the unit and the fuse (T2A 250V). Insufficient inlet pressure (less than 4 barg) can also cause this issue, so adjust the inlet pressure settings if needed. If the unit fails to de-pressurize, the solenoid valve may not be functioning correctly; if there is power to the coil, replace the valve. Finally, check the inlet air supply if the outlet flow stops.
  • T
    thomashoAug 17, 2025
    Why is my NANO Dehumidifier showing poor dew point performance?
    • C
      Charles CrawfordAug 17, 2025
      Poor dew point performance in your NANO Dehumidifier can stem from several factors. Ensure the inlet pressure is at least 4 barg, adjusting the inlet pressure settings if necessary. An electrical fault could also be the cause, so ensure the power is on, the dryer front panel is illuminated, and the dryer is cycling correctly. Check for moist or contaminated desiccant; if present, eliminate the source of contamination and replace the cartridges. Also, verify that the dryer's performance matches the required system air consumption and check the inlet air temperature against the technical specifications. Insufficient purge air, which requires adjustment by service personnel, or a blocked exhaust silencer, also requiring service, could be responsible.
  • K
    Kimberly BarryAug 25, 2025
    What to do if my NANO NDL-2130 Dehumidifier has constant depressurisation?
    • J
      Julia BradyAug 25, 2025
      If your NANO Dehumidifier is constantly depressurizing, try switching it off and restarting it. Ensure the dryer is pressurized before powering it on to allow it to initialize before commencing operation. Erratic airflow from the exhaust may also indicate a faulty or damaged valve, requiring service.
  • S
    Sabrina AcostaSep 1, 2025
    How to fix constant depressurization in NANO Dehumidifier?
    • S
      Samantha McgeeSep 1, 2025
      Constant depressurization in your NANO Dehumidifier can occur if the dryer fails to initialize. Try switching the dryer off and then restarting it. Ensure the dryer is pressurized before powering it on to allow proper initialization before operation. Erratic airflow from the exhaust may also indicate a faulty or damaged valve, requiring service.

Summary

General Information and Safety

General Safety Precautions

Warnings against modifications and requirements for trained personnel.

Technical Specifications

Installation Guidelines

Standard Controller Operation

Standard Controller Remote Functions

Standard Controller Emergency Stop

Standard Controller Shutdown

Standard Controller Performance Monitoring

Dew-Point Display and ES Mode

Explains dew-point display and energy saving mode activation.

Adjusting Dewpoint Settings

Guide on how to access and modify ES and dewpoint alarm settings.

Standard Controller ES Model Features

Standard Controller Modbus Connectivity

Premium Controller Operation

Startup and Pressurization

Steps for powering on and pressurizing the unit with premium controller.

Electrical Grounding

Importance and procedure for proper electrical grounding.

Premium Controller HMI Features

Premium Controller Remote Start;Stop

Remote Start;Stop Setup

Steps to access and wire the remote start/stop function for premium controller.

Remote Control Wiring

Details the six wires and their functions for remote control.

Control Wire Voltage Warning

Warning about applying external voltage to control wires.

Premium Controller Emergency Stop

Emergency Stop Functionality

Steps to access and wire the emergency stop feature for premium controller.

Emergency Stop Wiring

Outlines the wiring connections for the emergency stop.

Premium Controller Shutdown

Depressurization Procedure

Instructions for safely depressurizing the unit with premium controller.

System Isolation

Emphasizes isolating the unit from air and electrical supply.

Premium Controller Performance Monitoring

Maintenance Procedures

Service Schedule and Tasks

Troubleshooting Guide

Poor Dew-Point Performance Issues

Lists causes and solutions for poor dew-point performance.

Dryer Cycling Problems

Identifies common reasons and fixes for cycling issues.

Standard Controller Wiring Diagram

Premium Controller Wiring Diagram

NANO NDL-2130 Specifications

General IconGeneral
BrandNANO
ModelNDL-2130
CategoryDehumidifier
LanguageEnglish

Related product manuals