KEYPAD FUNCTIONS
9. Reset System Trouble? System troubles display and sound at the keypad.
Correcting the trouble will clear most indications, however the following error codes will
require manual reset: E11; E13; E19; E20 and E22. (See SYSTEM TROUBLE ERROR
CODES for a description of error codes).
10. Reset Sensor Watch Failure (Sensor Watch programmed? YES NO).
Your system may have been programmed for Sensor Watch, a feature which supervises
the motion sensors in the system. If a Sensor Watch failure occurs, a System Trouble
E22-NN will result, where NN represents the zone number of the sensor in question. To
reset, press
C to clear the display, enter the Function Menu, scroll to Reset Sensor
Watch Failure and press
D. If you cannot correct the problem, call for service.
11. Start Exit Time? (Optional) (Start Exit Time programmed? YES NO)
In Commercial Burglary systems, exit delay may have been programmed to start after a
central-station “ringback” (verification) signal has been received. If the ringback tone
has not been received within about 30 seconds after arming, a communication problem
may exist. Use this function to start exit delay manually, then exit the premises
immediately. Be sure to have your alarm specialist check communications with the
central station as soon as possible.
09
INTERIOR
BYPASS FIRE/TBL SYS TBL CHIME
11
INTERIOR
BYPASS FIRE/TBL SYS TBL CHIME
10
INTERIOR
BYPASS FIRE/TBL SYS TBL CHIME

Other manuals for NAPCO GEM-RP3DGTL

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NAPCO GEM-RP3DGTL and is the answer not in the manual?

NAPCO GEM-RP3DGTL Specifications

General IconGeneral
BrandNAPCO
ModelGEM-RP3DGTL
CategoryKeypad
LanguageEnglish

Related product manuals