StarLink
SLE Series Alarm Communicators -- Installation Instructions 11
TELCO
T300
RJ31X
Wiring Diagram for PRIMARY Reporting Configuration
GEM-P801 Control Panel
(Use when telephone line is NOT available)
CONTROL PANEL PC BOARD
6 7 8
17 16 15 14 13 12 11
9
10 2
3 4 5
1
19 18
(CONTROL PANEL HOUSING)
6 7 8 15 14 13 12 11 9 10 2* 3 4 5 1*
+12V
()
PGM1 PGM2 PGM3 IN1 IN2 GND IN3 RING
PANEL
RING
TIP
2.2K
17 16
PANEL
TIP
RTS
(R)
PANEL
TX (B)
PANEL
RX (G)
StarLink Radio Terminals
~ ~
~ ~
AUX POWER
(–) (+)
*Refer to section
"SUPPLYING
POWER".
CTS
Y
ZONE (+)
DEDICATED
TO RADIO
SUPERVISION
NON-POLARIZED
NON-POLARIZED
(STARLINK RADIO HOUSING)
J600
A
B
Jumper (J600)
(located only on
models SLE-CDMA-
8D and SLE-GSM-
8D-3/4G) must be
placed on
"B" (bottom two pins)