EasyManua.ls Logo

NAPCO StarLink SLE Series - Wiring Diagram: Primary Reporting Configuration GEM-P801 (Cont.)

NAPCO StarLink SLE Series
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12 StarLink
SLE Series Alarm Communicators -- Installation Instructions
TELCO
T300
RJ31X
Wiring Diagram for PRIMARY Reporting Configuration
GEM-P801 Control Panel
(Use when telephone line is NOT available)
CONTROL PANEL PC BOARD
6 7
8 17 16 15 14 13 12 11 9 10 2
3 4 5
1
19 18
(CONTROL PANEL HOUSING)
~ ~
AUX POWER
(–) (+)
16VAC
*Refer to section "SUPPLYING POWER".
6 7 8 15 14 13 12 11 9 10 2* 3 4 5 1*
+12V
()
PGM1 PGM2 PGM3 IN1 IN2 GND IN3 RING TIP
17 16
RTS
(R)
PANEL
TX (B)
PANEL
RX (G)
CTS
Y
StarLink Radio Terminals
PANEL
RING (+)
PANEL
TIP (–)
(STARLINK RADIO HOUSING)
16VAC
Transformer
Optional: When Power Supply
SLE-SMTCHG is not used,
connect Panel Aux Power to
StarLink terminals 1 and 2
(observing polarity)
J600
A
B
Jumper (J600)
(located only on
models SLE-CDMA-
8D and SLE-GSM-
8D-3/4G) must be
placed on
"B" (bottom two pins)
to enable remote
downloading.