22
WI1370 XP-400 Installation Instructions
Site
At the site perform the following three steps:
1. Arm the panel.
2. Disarm the panel.
3. Enter
A6
. The panel will now call
the download computer running
PCPreset. PCPreset will answer the
call, establish a connection, and then
download the account that matches the
Auto Download ID Number [93] with the
account of the same number in the list
that PCPreset is currently running.
Dealer Programming
[94]Dealer Code
The default Dealer Code is
4567
. Program
a new 4-digit Dealer Code. When the panel
is defaulted the Dealer Code will be
changed back to the default Dealer Code of
4567
only if Dealer Code Lockout [96-1]
has not
been programmed.
[95]User 1 Code
The 1st User code is a program code as
well as an Arm/Disarm code. The default
User Code is
1234
. If User 1 Code Lockout
is programmed the User 1 Code cannot be
programmed from User Program Mode.
[96]Dealer Options 1
(1) Dealer Code Lockout
- Program to
prevent the Dealer Code from changing with
a panel default.
(2) User 1 Code Lockout
- If programmed
the User 1 Code cannot be programmed
from User Program Mode.
(3) Reserved
(4) Reserved
[97]Dealer Options 2
(1) International Dialing Protocol - No
dialing if no dial tone, 60 seconds between
attempts and 4 s wait for dial tone.
(2) Invert Bell Output - Inverts the Bell
polarity and removes supervision from the
bell circuit.
(3) System Trouble Auto Restore
-
Normally, System troubles require
acknowledgment (View System Trouble) in
order to restore. If this option is selected
troubles will restore without requiring
acknowledgment.
(4) User 1 Code-Program only
- If enabled
User 1 Code will function only as the User
Program Code and will not Arm/Disarm the
panel.
Note: All programming within Programming
Blocks [96] & [97] will not
change if the
panel is defaulted.
[98] Number of Re-Dials
The Number of re-dial attempts made by the
panel before indicating a Fail-to-
Communicate.

Other manuals for NAPCO XP-400