2.2 SPECIFICATIONS
ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE
WITH LOCAL CODES. IN THE ABSENCE OF LOCAL CODES, USE THE CURRENT CSA C22.1
CANADIAN ELECTRIC CODE (IN CANADA) OR THE ANSI/NFPA NO. 70 NATIONAL ELECTRIC CODE
IN THE UNITED STATES.
DO NOT CONNECT THIS APPLIANCE TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE. DO
NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM.
PROVIDE ADEQUATE CLEARANCE FOR SERVICING AND OPERATING THE APPLIANCE.
PROVIDE ADEQUATE VENTILATION.
NEVER OBSTRUCT THE FRONT OPENING OF THE APPLIANCE.
OBJECTS PLACED IN FRONT OF THE APPLIANCE MUST BE KEPT A MINIMUM OF 48” FROM THE
FRONT FACE OF THE APPLIANCE.
!
WARNING
Electrical Rating 115 Volts, 3.6 Amps, 60Hz
Watts During Start-Up Sequence 400 (approximately)
Watts During Operation 180 (approximately)
NPS45 Width 22 3/8"
NPS45 Height 30 1/2"
NPS45 Depth 26 5/8"
Weight 210 Pounds
Exhaust Collar 3"
Intake Collar 2"
NPS45 Hopper Capacity 55 Pounds
NPI45 Hopper Capacity 45 Pounds
EPA Exempt
Minimum Appliance Opening Size Front: 32.5/8"* W x 20 5/8 H x 14 1/4 D Back: 20 3/8 W
Approximate Maximum Heating Capacity (in square feet)* 800 to 2000 Sq. Feet
Burn Rate (Pounds per Hour)** 1.0 to 5.0
BTU/h** 8500 to 42500
Maximum Burn Time on Low Burn** 55 Hours (NPS45), 45 Hours (NPI45)
Hopper Capacity 55 Pounds (NPS45), 45 Pounds (NPI45)
* Heating capacity will vary depending on the home's oor plan, degree of insulation, and the outside temperature. It is
also affected by the fuel size, quality, and moisture level.
** Small pellets will increase or decrease the stated burn rates and burn times. Differences of plus or minus 20% depend-
ing on fuel quality may occur.
2.2.1 HEATING SPECIFICATIONS
2.3 GENERAL INSTRUCTIONS
* In order to install ashing ush to nished wall and centered within the opening the front opening of the appliance or
enclosure must be 32 5/8" wide.