DIAGNOSTICMANUAL
NOTEAnyactiveaftertreatmentsystemfaultcode(s)mayinhibitaRegen.Diagnoseactivefault
code(s),otherthanSPN3719(DPFSootLoad),beforecontinuing(seeElectronicControlSystems
Diagnostics”inEngineDiagnosticManual).
Table182CheckActiveRegenInhibitors
1.TurnignitionswitchtoONposition,engineOFF.
2.UsingServiceMaxx™software,loadtheAftertreatmentsession.
3.Startengineandrunvehiclespeedabove5mph.
4.VerifyalllistedinhibitorsaredisplayingNotInhibited.
Check
ExpectedResults
Comment
AFTRegenInhibit
Status
NotInhibited
Ifinhibited,correctthecause.CheckswitchesandanyDTC
thatmaybecausingtheRegeninhibit.
RedStopAlertLampOffIfOn,Regencan'tberun.Gotoappropriateaftertreatment
systemdiagnosticssectioninthismanual.
RegenInhibitSwitchOffIfOn,turnswitchOff.IfswitchdoesnotturnOff,then
diagnosecircuitfault.
PTOEnableSwitchOffIfOn,turnswitchOff.IfswitchdoesnotturnOff,then
diagnosecircuitfault.
PTOSwitchOffIfOn,turnswitchOff.IfswitchdoesnotturnOff,then
diagnosecircuitfault.
IfnoinhibitorsareactiveandRegenisneeded,gotoParkedRegenChecks(page155).
153
https://www.truck-manuals.net/

Table of Contents

Other manuals for Navistar MaxxForce 10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Navistar MaxxForce 10 and is the answer not in the manual?

Navistar MaxxForce 10 Specifications

General IconGeneral
BrandNavistar
ModelMaxxForce 10
CategoryEngine
LanguageEnglish

Related product manuals