DIAGNOSTICMANUAL
15.2.ENTRYCONDITIONS
Overview
ARegenmaynotoccurduetoanyofthefollowingconditions:
Inhibitorsdonotmatchtheirexpectedvalue
Entryconditionshavenotbeenmet
Activefaultcode(s)
ToviewthestatusofRegeninhibitors,useanElectronicServiceT ool(EST)withServiceMaxx™software,go
toT ests>KOERAftertreatmentT ests>OnboardFilterCleanlinessT est.SelecttheInhibitorstab.
NOTEAnyactiveaftertreatmentsystemfaultcode(s)mayinhibitaRegen.Diagnoseactivefaultcode(s)
beforecontinuing(seeElectronicControlSystemsDiagnostics”inEngineDiagnosticManual)
Table185EntryConditionsforanActiveRegen
WhentheECMdeterminesthesootlevelthresholdisreached,thesystemtriggersDPFRegen.
NOTEShorttripsorstopandgodrivingcouldpreventasuccessfulRegen.
ThefollowingconditionsarerequiredforanActiveRegen:
DPFStatussignaldisplaying:RegenNeeded
Redstopenginelampnoton
EngineCoolantTemperatureisaboveoratleast170ºF(75ºC)
InhibitingDTCsmustnotbeactive
RegenInhibitswitchnotactive(switchmustbeoff)
PTOnotactive(switchmustbeoff)
ExhaustT emperaturesensorsbelowsafethresholds:
DOCITbelow932°F(500°C)
DOCOTbelow120°F(650°C)
DPFOTbelow1382°F(750°C)
IfDPFStatusdisplaysRegenneededandvehicleisunabletoperformanActiveRegen,gotoappropriate
aftertreatmentsystemdiagnosticssectioninthismanual.
156
https://www.truck-manuals.net/

Table of Contents

Other manuals for Navistar MaxxForce 10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Navistar MaxxForce 10 and is the answer not in the manual?

Navistar MaxxForce 10 Specifications

General IconGeneral
BrandNavistar
ModelMaxxForce 10
CategoryEngine
LanguageEnglish

Related product manuals