DIAGNOSTICMANUAL
Actions:
1.WhenEGRvalveiscommandedON,verifyIntakeManifoldPressure(IMP)signalvaluedrops.
2.WhenEGRvalveiscommandedON,verifyMassAirFlow(MAF)MeanValue(MMV)drops.
CalculatethedifferencebetweenMMVatastabilizedhighpointandastabilizedlowpoint,then
comparetothetablebelow.
Engine
MAFMeanValue(MMV)
Difference
Tolerance
MaxxForce®DT
215-230HP
6901000
Lessthan690FailsAMST est
MaxxForce®DT
245-300HP
7401000
Lessthan740FailsAMST est
MaxxForce®9and10
300-350HP
8501130
Lessthan850FailsAMST est
NOTEEGRvalvepositionwillneverreadlessthan35%andisconsideredclosed.