EasyManua.ls Logo

Navistar MaxxForce 9

Navistar MaxxForce 9
197 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DIAGNOSTICMANUAL
Table187EntryConditionsforaParkedRegen
AParkedRegencanonlybeperformedwhentheDPFsootlevelthresholdisreached.TheDPFlampwill
ashorstayonsolid,signalingtheneedforRegen.
ThefollowingconditionsarerequiredforaParkedRegen:
EngineRunning
DPFlampison
ParkedRegenswitchon
DPFStatussignaldisplaying:RegenNeeded
Redstopenginelampnoton
EngineCoolantTemperatureisaboveoratleast170ºF(75ºC)
Vehiclespeednotrolling
InhibitingDTCsmustnotbeactive.GotoRegenInhibitorspage152
RegenInhibitswitchnotactive(switchmustbeoff)
PTOnotactive(switchmustbeoff)
ExhaustT emperaturesensorsbelowsafethresholds:
DOCITbelow932°F(500°C)
DOCOTbelow1202°F(650°C)
DPFOTbelow1382°F(750°C)
OnboardFilterCleanlinessTest.DPFStatusdisplays“Regenneeded”andvehicleisunabletoperformanActive
Regen,gotoappropriateaftertreatmentsystemdiagnosticssectioninthismanual.
158
https://www.truck-manuals.net/

Table of Contents

Other manuals for Navistar MaxxForce 9

Related product manuals