Chapter 6: Touch Screen Calibration – Windows 6-9
Verifying the Calibration
1. SelecttheToolstab.
2. SelecttheDrawing Testbutton.
3. Testthecalibrationonthedrawscreen.
Touchthescreeninvariousspotsandtraceeachofthehorizontalandvertical
lines,includingtheborderaroundthescreen.
Inthistest,alltouchesarepersistent,includingtouchdowns(greendots)and
touchups(reddots).
Aftertracingthelines,reviewthedrawnlinestomakesuretheycloselyfollowthe
underlyingpattern.Paycloseattentiontotheedgesofthedisplayandthecorners
sincethisiswhereanincorrectcal
ibrationismostnoticeable.Ifalineorpoint
appearstobeoutsidethepattern,trypressingtheareatoseehowfarthecursoris
fromthetouchpoint.Iftheregisteredtouchisgreaterthan7mmawayfrom
wherethetouchoccurred,repeatthecalibration.
4. SelectExittoclosethisscreenandtoreturntotheMicro
chipTSHARCControl
Panel.
5. SelecttheCalibrationtabtorepeatthecalibrationprocedureorselectApplyand
thenOKifyouaresatisfiedwiththeresultsandwanttoclosetheapplication.