page
OP code Parameter Remarks
AUTO DIMMING
ROOM LIGHT SENSING
MODE 10h C8h 0: No mean
1: OFF
2: MODE1
3: MODE2
BACKLIGHT SETTING
MAX LIMIT 10h C9h 0 – 100(64h)
IN BRIGHT 10h 33h
0 – 100(64h)
IN DARK 10h 34h 0 – 100(64h)
SENSING LUX 02h B4h Current Illuminance read Read only
POWER INDICATOR
POWER INDICATOR 02 BEh 0: No mean
1: Off
2: On
SCHEDULE INDICATOR 11h 71h 0: No mean
1: Off
2: On
CEC
CEC 11h 76h 0: No mean
1: OFF
2: ON
AUTO TURN OFF 11h 77h 0: No mean
1: NO
2: YES
AUDIO RECEIVER 11h 78h 0: No mean
1: NO
2: YES
SEARCH DEVICE 11h 79h 0: No mean
1: NO
2: YES
RESET
(CONTROL)
02h CBh 0: No mean
Category
Momentary
SYSTEM
MONITOR INFORMATION
MODEL NAME Refer to chapter 14
SERIAL Refer to chapter 14
CARBON SAVINGS
10h 10h
(g)
/11h
(kg)
0 – 999(3E7h)(g)
0 – 65535(FFFF
h
)(kg)
Read Only
CARBON USAGE 10h 26h
(g)
/27h
(kg)
0 – 999(3E7
h
)(g)
0 – 65535(FFFF
h
)(kg)
Read Only
FIRMWARE Refer to chapter 17
MAC ADDRESS Refer to Chapter 21
FACTORY RESET 02h CBh 0: No mean
1: Factory Reset
Momentary