English-53
English
SNMP Setting
Click “SNMP” on the left side of HOME.
This function allows for getting status and controlling of a monitor via the network.
Version:
SNMP v1 Authenticated plaintext by community name, not return a confi rmation message of Trap.
SNMP v2c Authenticated plaintext by community name, return a confi rmation message of Trap.
Community name:
The default setting of community name is “public”. It is read only. You can set community names for up to 3 settings.
Trap:
Sending error message to specifi ed address when an error occurs in the monitor.
Check Box Explanation Error code
Temperature Temperature abnormal 0xA0, 0xA1, 0xA2
Fan Cooling fan abnormal 0x80, 0x81
Power Power abnormal 0x70, 0x71, 0x72, 0x78
Inverter/Backlight Inverter or backlight abnormal 0x90, 0x91
No Signal No signal 0xB0
PROOF OF PLAY Lower the log storage 0xD0
System Error System error 0xE0
AMX Setting
Click “AMX” on the left side of HOME.
AMX BEACON Turn on or off for detection from AMX Device Discovery when connecting to the network supported by
AMX’s NetLinx control system.
TIP:
When using a device that supports AMX Device Discovery, all AMX NetLinx control system will
recognize the device and download the appropriate Device Discovery Module from an AMX server.
Checking [ENABLE] will detect the device from AMX Device Discovery.
Checking [DISABLE] will not detect the device from AMX Device Discovery.
CRESTRON Setting
Click “CRESTRON” on the left side of HOME.
CRESTRON ROOMVIEW compatibility
The monitor supports CRESTRON ROOMVIEW, allowing multiple devices connected in the network to be managed and
controlled from a computer or a controller.
For more information, visit http://www.crestron.com
ROOMVIEW ROOMVIEW for managing from the computer.
ON: Enables ROOMVIEW.
OFF: Disables ROOMVIEW.
CRESTRON
CONTROL
CRESTRON CONTROL for managing from the controller.
ON: Enables CRESTRON CONTROL.
OFF: Disables CRESTRON CONTROL.
CONTROLLER IP
ADDRESS
Set your IP address of CRESTRON SERVER.
IP ID Set your IP ID of CRESTRON SERVER.
TIP: The CRESTRON settings are required only for use with CRESTRON ROOMVIEW.
For more information, visit
http://www.crestron.com