Chapter 1 Introduction
Page 1-24 NEAX2000 IPS Request for Proposal (RFP) Reference Guide
ND-24349, Issue 4
IPS
DM
System Capacity
Capacity Per MC
Number of PHYSICAL MODULAR CHASSIS
1 2 3
No. of ports 40 80 120
LT card Note 1
No. of cards 5 10 15
No. of ports Max. 256 ports per system
AP card
No. of cards 5 10 15
Total number of lines (Analog Single Line Telephone +
D
term
)
40 80 120
IP-PAD No. of channel 32 64 96
4LC w/RGU Card 20 40 60
8LC 40 80 120
Analog Single Line Telephone
(Lines) Note 2
Long Line Not Available
Standard 40 80 120
D
term
(Lines)
Long Line 10 20 30
D
term
IP/D
term
IP INASET (PTP Connection) 952 888 824
D
term
PS 512
Cell Station (CS) / Zone Transceiver (ZT) 12 24 36
ISDN Station 8 16 24
Loop Start 40 80 120
DID w/4DIT 20 40 60
Central Office Trunk (Lines)
2W/4W E&M 10 20 30
CCIS Trunk (Peer to Peer Connection) Max. 127
1.5M 5 DTI: 10, CCIS: 8
DTI/CCIS Digital Link
Note 3
2M 5 8
1.5M/2M(PRT) 5 8
2BRT (card) 5 10 15
ISDN
4BRT (card) 5 10 15
IP Trunk 1 2 3
PFT Connections 4 8 12
3-Party Conference Max. 16 conference groups per system
6-Party Max. 4 conference groups per system
6-/10-Party Conference
10-Party Max. 2 conference groups per system
32-Party Conference 5
Max. 8 conference groups
per system