FEATURES FOR OTHER COUNTRIES ONLY
MFC-INCOMING CALL/MFC-OUTGOING CALL
– 606 –
A2594-10
PROGRAMMING
(1) MFC Signaling Common Data Assignment
DESCRIPTION DATA
Assign the AP number to MFC trunk.
The AP number must match the SENSE
and changeover switch settings on the
MFC trunk card.
(1)
(2)
Y=0
04-15, 20-31: AP No.
08: MFC trunk
Assign MFC Trunk number to each MFC
trunk.
(1)
(2)
Y=04
00-15: MFC trunk No.
XX Z
XX: 04-15, 20-31: AP No. assigned by
CM05
Z : 0-3: Circuit No.
Assign the MFC PAD control level to Back-
ward signals.
(1)
(2)
Y=1
0: MFC PAD control (PAD Level)
0: –8 dBm, 1: –10 dBm
2: –11.5 dBm, 3: –9.13 dBm
4-7 : Not used
Assign the sensitive level of MFC Sender
and Receiver.
(1)
(2)
Y=1
1: Sensitive level of MFC Sender and
Receiver (PAD Level)
00: –26 dBm, 01 : –27 dBm
02: –28 dBm, 03 : –29 dBm
04: –30 dBm, 05 : –31 dBm
06: –32 dBm, 07 : –33 dBm
08: –34 dBm, 09 : –35 dBm
10: –36 dBm, 11 : –37 dBm
12: –39 dBm, 13 : –40 dBm
14: –41 dBm, 15 : –38 dBm