EasyManua.ls Logo

NEC NEAX 7400 ICS M100MX - Page 627

NEC NEAX 7400 ICS M100MX
1200 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FEATURES FOR OTHER COUNTRIES ONLY
MFC-INCOMING CALL/MFC-OUTGOING CALL
– 607 –
A2594-10
DESCRIPTION DATA
Assign the number of received digits of
station number from PSTN.
NOTE: If no data is assigned, the MFC
Signaling can not be provided.
(1)
(2)
Y=1
2: Number of received digits of station
number from PSTN
01-31: 1 digit-31 digits
Assign the MFC Sender and Receiver to
each circuit.
NOTE: The first data (AP number 0-3)
corresponds to the AP numbers
(X, Y, Z, W: 04-15, 20-31) as-
signed by CM05, as shown be-
low.
CM31 Y=2 CM05 Y=0
AP number 0: AP number X
AP number 1: AP number Y
AP number 2: AP number Z
AP number 3: AP number W
(X<Y<Z<W)
(1)
(2)
Y=2
0-3: AP No.
0 : All circuit are assigned as Sender
1 : Circuit No. 0, 1: Sender
Circuit No. 2, 3: Receiver
2 : Circuit No. 0, 1: Receiver
Circuit No. 2, 3: Sender
3 : All circuits are assigned as Receiv-
er
END
CM31