Issue 1.0 UNIVERGE SV8100
3 - 34
SECTION 13 SV8100NET TRACE USING THE ISDN DEBUG TRACE (MAIL IN
0012)
10:53:20 >>mail in 0 0 1 2
10:53:23 >>
Enter ISDN debug mode
master current bid : 08H
master current line : 00H
ACD Data Size error. or socket close...
<<< KAN : sta_org_target_dial_set >>> sta_port:0401h, dial:0000h
<<< KAN : sta_org_target_dial_set >>> sta_port:0401h, dial:0aa2h
<<< prgrd1501.cpp(38) read_s_sta_clip_enable >>> port : 0, data : 1
S ISDN : >>>>>>>>>>>>>>>>
74 A1 04 01 01 00 USL(7,1),SETUP REQ
08 02 00 08 05 Callref:ORG(8),SETUP
04 03 80 90 A3 Bearer capability [speech]
18 03 A9 83 81 Channel identification
6C 05 00 83 35 30 30 Calling party number [500]
70 04 81 32 30 30 Called party number [200]
7C 03 80 90 A3 Low layer compatibility
7D 02 91 81 High layer compatibility
7E 46 00 03 04 01 08 00 User-user [70 octets]
+00 04 0C 45 58 54 20 35
+30 30 20 20 20 20 20 1A
+01 00 05 01 01 13 01 01
+21 01 00 2E 01 00 3B 04
+01 04 00 00 07 01 01 02
+01 01 24 01 02 2B 11 11
+00 00 00 00 00 00 00 00
+00 00 00 00 00 00 00 00
A1 Sending complete
Tone information for port E001H
Timeslot : 0101H
Level : Tx=20H, Rx=20H
Current : 0000H Level=20H
Sender : Not opened
R ISDN : <<<<<<<<<<<<<<<<
54 0B A1 02 01 01 00 USL(0,0),CALL PROCEEDING IND
08 02 80 08 02 Callref:DES(8),CALL PROCEEDING
7E 46 00 25 01 02 04 0C User-user [70 octets]
+45 58 54 20 32 30 30 20
+20 20 20 20 1A 01 00 05
+01 01 13 01 01 21 01 00
+2E 01 00 3B 04 01 04 00
+00 07 01 01 02 01 01 24
+01 02 2B 11 11 00 00 00
+00 00 00 00 00 00 00 00
+00 00 00 00 00 02 01 01
R ISDN : <<<<<<<<<<<<<<<<
42 0B A1 01 01 01 00 USL(0,0),ALERTING IND
08 02 80 08 01 Callref:DES(8),ALERTING
1E 02 81 82 Progress indicator
7E 30 00 0A 04 A2 0A 00 User-user [48 octets]
Keyphone port 01 dials
200.
Call sent using VOIPU
blade in slot 7 circuit 1.
Setup message contains
calling party name (ASCII
HEX):
45 58 54 20 35 30 30 =
EXTN 500
This is shown on the
LCD display.
Received SV8100Net
events always use
USL 0,0
Remote SV8100
returns the called
party name (ASCII HEX):
45 58 54 20 32 30 30 =
EXTN 200
This is shown on the
LCD display.