NCFEN
14
2.6 Noise emission risks
WARNING! Risk of personal injury.
• Vibraons and noise emission are directly correlated. Compliance with the instrucons
given for correct installaon so as to reduce vibraons to a minimum is of equivalent
importance for noise reducon.
• Avoid posioning fans in areas that could increase the noise risk.
• Avoid working posions that increase the noise risk for operaves.
• Reducing exposure mes and the use of Personal Protecon Equipment will reduce the
risks caused by exposure to noise emissions. See Figure 1.
• With sound pressures higher than 100 dBA, operaves may approach the fan only if it is
not operang, even if wearing Personal Protecon Equipment.
Since the noise emied by a fan can be inuenced by external factors that can aect the
overall noise level, such as:
• The dimensions of the environment in which the fan is installed.
• The presence of stac elements near the fan (e.g. walls).
• The presence of other machines that are also sources of noise emission.
Nederman invites the user to measure ambient noise levels. It should be noted that
the presence of other operang machines generates a “superimposion of eects” and
resonance that mulply ambient noise.
In addion, in cases of restricted environments, or if the fan is installed against walls, the
eect of reverberaon and resonance on structures (walls and ceiling) is “exponenal”.
The denion of the risks to workers of exposure to noise is not the responsibility of
Nederman, which limits itself to indicaons of values, levels of uncertainty, standards or
criteria used for noise emission measurements.
As envisaged by applicable legislaon, it is the user that must assess the level of exposure
of operaves to noise emissions using its own specic procedures, idenfying:
• Sources of noise and their relave importance.
• Average exposure mes for each operave.
• The level of direct and reected noise.
• The noise transmied by structures and not through the air.
If exposure to noise, in terms of sound pressure, exceeds 80 dBA, the employer must
provide operaves with PPE for the hearing, such as earplugs or earmus. If exposure is
equal to or higher than 85 dBA, the employer must take all possible acon to ensure that
PPE for the hearing is eecvely used.
3 Descripon
3.1 Intended use
The NCF fan is a centrifugal fan designed for use in all types of industrial process and
venlaon systems, mounted indoor as well as outdoor.
The fan must be used in the ow range specied in the performance diagrams. Use of the
fan with ows lower than the minimum value indicated in the diagrams may cause unstable
uid dynamic operaon and vibraons.