NCF 30/15 NCF 30/25 NCF 40/25 NCF 50/25 NCF 80/20 NCF 120/15 NCF 120/25 NCF 160/25
Voltage (V)
Current (A)
400Δ/690Y
7,8/4,5
400Δ/690Y
10,3/6,0
400Δ/690Y
10,3/6,0
400Δ/690Y
13,8/8,0
400Δ/690Y
13,8/8,0
Phase: 3~ 3~ 3~ 3~ 3~ 3~ 3~ 3~
Starng current 6 - 7 x rated
current
6 - 7 x rated
current
6 - 7 x rated
current
6 - 7 x rated
current
6 - 7 x rated
current
6 - 7 x rated
current
6 - 7 x rated
current
6 - 7 x rated
current
Degree of
protecon
IP 55 IP 55 IP 55 IP 55 IP 55 IP 55 IP 55 IP 55
Weight (kg) 67 105 110 112 150 132 232 292
Working
temperature
(°C)
Maximum
+60
Maximum
+60
Maximum
+60
Maximum
+60
Maximum
+60
Maximum
+60
Maximum
+60
Maximum
+60
Ambient
temperature
(°C)
-30 to +40 -30 to +40 -30 to +40 -30 to +40 -30 to +40 -30 to +40 -30 to +40 -30 to +40
Sound power
level Lw(A) ±
3dB *
94dB(A) 97dB(A) 106dB(A) 100dB(A) 98dB(A) 104dB(A) 107dB(A) 103dB(A)
Sound pressure
level Lp(A) ±
3dB *
80dB(A) 82dB(A) 83dB(A) 86dB(A) 83dB(A) 89dB(A) 92dB(A) 90dB(A)
*Reference standards: ISO 3744, ISO 3746, ISO 13347. Installaon Type D: ducted inlet, ducted outlet.
3.4.2 Technical data 60 Hz fans (metric)
Table 3-2: Technical data 60 Hz fans (metric)
NCF 30/15 NCF 30/20 NCF 30/25 NCF 40/25 NCF 50/25 NCF 80/20 NCF 120/15 NCF 120/25 NCF 160/25
Capacity (m
3
/h) 535 - 4180 700 - 4315 830 - 6000 910 - 6550 800 - 5600 1600 - 8540 2600 - 13980 2340 - 11650 2650 - 17140
Total pressure
(Pa)
1970 - 575 2890 - 950 2540 - 870 3640 - 1320 4540 - 1570 3170 - 1020 3590 - 1170 5260 - 1700 5060 - 1870
Motor power
(kW)
2,2 3,0 4,0 5,5 5,5 7,5 11 15 18,5
Speed (r/min) 3500 3515 3535 3510 3520 3550 3540 3550 3560
Voltage (V)
Current (A)
208
8,6
208
11,5
208
15,1
208
18,7
208
18,7
208
26,2
208
38,4
208
52
208
66,4
Voltage (V)
Current (A)
230YY/460Y
7,8/3,9
230YY/460Y
10,4/5,2
230∆∆/460∆
13,6/6,8
230∆∆/460∆
17/8,5
230∆∆/460∆
17/8,5
230∆∆/460∆
23,8/11,9
230∆∆/460∆
34,8/17,4
30∆∆/460∆
46,8/23,4
230∆∆/460∆
60/30
Voltage (V)
Current (A)
575 V
3,1 A
575 V
4,2 A
575 V
5,5 A
575 V
6,8 A
575 V
6,8 A
575 V
9,5 A
575 V
11,0 A
575 V
19,4 A
575 V
24 A
Phase 3 phase 3 phase 3 phase 3 phase 3 phase 3 phase 3 phase 3 phase 3 phase
Starng
current
6-7 x rated
current
6-7 x rated
current
6-7 x rated
current
6-7 x rated
current
6-7 x rated
current
6-7 x rated
current
6-7 x rated
current
6-7 x rated
current
6-7 x rated
current
Protecon IP 55 IP 55 IP 55 IP 55 IP 55 IP 55 IP 55 IP 55 IP 55
Weight (kg) 67 85 105 110 112 150 161 232 292
Working
temperature (°C)
Maximum
+60
Maximum
+60
Maximum
+60
Maximum
+60
Maximum
+60
Maximum
+60
Maximum
+60
Maximum
+60
Maximum
+ 60
*Reference standards: ISO 3744, ISO 3746, ISO 13347. Installaon Type D: ducted inlet, ducted outlet.

Other manuals for Nederman NCF Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nederman NCF Series and is the answer not in the manual?

Nederman NCF Series Specifications

General IconGeneral
BrandNederman
ModelNCF Series
CategoryFan
LanguageEnglish

Related product manuals