NCF
17
EN
NCF 30/15 NCF 30/20 NCF 30/25 NCF 40/25 NCF 50/25 NCF 80/20 NCF 120/15 NCF 120/25 NCF 160/25
Ambient
temperature (°C)
-30 to +40 -30 to +40 -30 to +40 -30 to +40 -30 to +40 -30 to +40 -30 to +40 -30 to +40 -30 to +40
Sound power
level Lw(A) ±
3dB *
94dB(A) 103dB(A) 97dB(A) 106dB(A) 100dB(A) 98dB(A) 104dB(A) 107dB(A) 103dB(A)
Sound pressure
level Lp(A) ±
3dB *
80dB(A) 89dB(A) 82dB(A) 83dB(A) 86dB(A) 83dB(A) 89dB(A) 92dB(A) 90dB(A)
*Reference standards: ISO 3744, ISO 3746, ISO 13347. Installaon Type D: ducted inlet, ducted outlet.
3.4.3 Technical data 60 Hz fans, 380 V (metric)
Table 3-3: Technical data 60 Hz fans (metric)
NCF 30/15 NCF 30/20 NCF 30/25 NCF 40/25 NCF 50/25 NCF 80/20 NCF 120/25 NCF 160/25
Capacity (m
3
/h) 830 - 6000 910 - 6550 800 - 5600 1600 - 8540 2340 - 11650 2650 - 17140
Total pressure
(Pa)
2540 - 870 3640 - 1320 4540 - 1570 3170 - 1020 5260 - 1700 5060 - 1870
Motor power
(kW)
4,0 5,5 5,5 7,5 15 18,5
Speed (r/min) 3535 3510 3520 3550 3550 3560
Voltage (V)
Current (A)
380∆
8,2
380∆
10,8
380∆
10,8
380∆
14,5
380∆
27,9
380∆
34
Phase 3 phase 3 phase 3 phase 3 phase 3 phase 3 phase
Starng
current
6-7 x rated
current
6-7 x rated
current
6-7 x rated
current
6-7 x rated
current
6-7 x rated
current
6-7 x rated
current
Protecon IP 55 IP 55 IP 55 IP 55 IP 55 IP 55
Weight (kg) 105 110 112 150 232 292
Working
temperature (°C)
Maximum
+ 60
Maximum
+ 60
Maximum
+ 60
Maximum
+ 60
Maximum
+ 60
Maximum + 60
Ambient
temperature (°C)
-30 to +40 -30 to +40 -30 to +40 -30 to +40 -30 to +40 -30 to +40
Sound power
level Lw(A) ±
3dB *
95dB(A)
97dB(A) 96dB(A) 95dB(A) 101dB(A) 102dB(A)
Sound pressure
level Lp(A) ±
3dB *
82dB(A) 83dB(A) 86dB(A) 83dB(A) 89dB(A) 90dB(A)
*Reference standards: ISO 3744, ISO 3746, ISO 13347. Installaon Type D: ducted inlet, ducted outlet.
3.4.4 Technical data 60 Hz fans (imperial)
Table 3-4: Technical data 60 Hz fans (imperial)
NCF 30/15 NCF 30/20 NCF 30/25 NCF 40/25 NCF 50/25 NCF 80/20 NCF 120/15 NCF 120/25 NCF 160/25
Capacity (cfm) 315 -
2466
410 -
2540
490 -
3535
535 -
3855
470 -
3300
940 -
5025
1530 -
8230
1375 -
6855
1560 -
10090
*Reference standards: ISO 3744, ISO 3746, ISO 13347. Installaon Type D: ducted inlet, ducted outlet.

Other manuals for Nederman NCF Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nederman NCF Series and is the answer not in the manual?

Nederman NCF Series Specifications

General IconGeneral
BrandNederman
ModelNCF Series
CategoryFan
LanguageEnglish

Related product manuals