All Rights Reserved. January 2016 Part No. 729-110-043 Rev. 1.02
Weld parameters above were established as optimum for conditions in our lab.
Heavy base plate material was used for physical testing purposes. Local conditions
and/or plate thickness differences may necessitate parameter adjustments.
Weld parameters above were established without the use of 10% detergent
solution. If detergent solution is preferred, the amount of weld heat will generally
have to be increased, i.e., increase voltage and/or reduce spring pressure.
Aluminum alloy 3003 was used to set the above parameters. Other alloys may require
parameter adjustments.
If settings are needed (or desired) other than those listed above, please consult your Nelson