18
Version: 9a
13.11.2018
EN
NOTE:
Press and hold the button
approx. 2 seconds to enter the setup menu.
Press the button again to exit the setting menu.
Press the button
to conrm the settings and move to the next setting point.
This will allow you to navigate through the setup menu.
This procedure applies to all subsequent setting points!
COMBUSTION FAN’S AND BLOWER’S SPEED SETTING
Press and hold the button
approx. 2 seconds to enter the setup menu.
The screen will display:
S= SMOKE(EXHUAST FAN) F=FAN(BLOWER)
Press
to move from “S 0” TO “F 0”. Press to adjust their speed.
Both of them can be adjusted from 20 to -20. Normally, factory setting is 0. 20 is max. and -20 is min.
Press
to save the setting and go to the subsequent setting points P2, P3 and P4.