EasyManua.ls Logo

Neoway G2 Series - CAS02-Set Update Frequency of Position Fix; CAS03-Enable or Disable Message Output

Default Icon
29 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
G2 & G7A
Commands Manual
Copyright © Neoway Technology Co., Ltd
9
5.4
CAS02-
Set Update Frequency of Position Fix
Identifier
CAS02
Description
Set Update Frequency of Position Fix
Type
Input
Format
$PCAS02,fixInt*CS<CR><LF>
Example
$PCAS02,1000*2E
Parameter Description
Field
Name
Format
Parameter Description
1
$PCAS02
Character string
Message ID, sentence header
2
fixInt
Numeric value
Interval between position fix updates, unit: ms
1000=1Hz, 1 position fixed is output every second
500=2Hz, 2 position fixed is output every second
250=4Hz, 4 position fixed is output every second
200=5Hz, 5 position fixed is output every second
100=10Hz, 10 position fixed is output every second
3
CS
HEX numeric
value
Checksum, exclusive OR (no start or stop bits) of
all characters in the sentence, including "," and "^"
delimiters, between but not including the "$" and
the "*" delimiters.
4
<CR><LF>
Character
Carriage return and line feed
5.5
CAS03-Enable or Disable Message Output
Identifier
CAS03
Description
Enable or disable the output of NMEA messages
Type
Input
Format
$PCAS03,nGGA,nGLL,nGSA,nGSV,nRMC,nVTG,nZDA,nANT,nDHV,nLPS,res,res,
nUTC*CS<CR><LF>
Example
$PCAS03,1,1,1,1,1,1,1,1,0,1,0,0,1,0*02
Parameter Description