12
Format
$PCAS05,ver*CS<CR><LF>
Example
$PCAS05,1*19
Parameter Description
Field
Name
Format
Parameter Description
1
$PCAS05
Character string
Message ID, sentence header
2
Mode
Numeric value
Set NMEA protocol type (Remark [1])
3
CS
HEX numeric
value
Checksum, exclusive OR (no start or stop bits) of
all characters in the sentence, including "," and "^"
delimiters, between but not including the "$" and
the "*" delimiters.
4
<CR><LF>
Character
Carriage return and line feed
Remark [1] NMEA protocol types
2
Compatible with NMEA 4.1 and later versions
5
Compatible with the BDS/GPS Dual-GNSS protocol of China Transport
Telecommunications & Information Center (CTTIC), NMEA 4.0 protocol and
versions later than NMEA 2.3
9
Compatible with NMEA0183 GPS protocol and NMEA 2.2
5.8
CAS10-Set Start Mode
Identifier
CAS10
Description
Restart the receiver
Type
Input
Format
$PCAS10,rs*CS<CR><LF>
Example
$PCAS10,0*1C hot start
$PCAS10,1*1D warm start
$PCAS10,2*1E cold start
$PCAS10,3*1F factory start
Parameter Description
Field
Name
Format
Parameter Description
1
$PCAS10
Character string
Message ID, sentence header