G2 & G7A
Commands Manual
Copyright © Neoway Technology Co., Ltd
24
$GPTXT,01,01,01,ANTENNA OK*35
$GPTXT,01,01,01,ANTENNA SHORT*63
Parameter Description
Field
Name
Format
Parameter Description
1
$GPTXT
Character string
Message ID, TXT sentence header
2
Xx
Numeric value
Total number of sentences, 01 to 99
Depending on the length of text message, multiple
messages of GPTXT are required.
For G2 and G7A, this field is fixed to 01.
3
Yy
Numeric value
Sentence number, 01 to 99
For G2 and G7A, this field is fixed to 01.
4
Zz
Numeric value
Text identifier
For G2 and G7A, this field is fixed to 01.
5
info
Text message
ANTENNA OPEN
ANTENNA OK
ANTENNA SHORT
6
CS
HEX numeric
value
Checksum, exclusive OR (no start or stop bits) of
all characters in the sentence, including "," and "^"
delimiters, between but not including the "$" and
the "*" delimiters.
7
<CR><LF>
Character
Carriage return and line feed
6.10
DHV-Design Hourly Volume
Identifier
DHV
Description
Details of GNSS receiver speeds
Type
Output
Format
$--DHV,UTCtime,speed3D,spdX,spdY,spdZ,gdspd*CS<CR><LF>
Example
$GNDHV,021150.000,0.03,0.006,-0.042,-0.026,0.06*65
Parameter Description