NETAFLEX™ 3G INSTALLATION MANUAL
INSTALLATION
Dual dosing channel
If the NetaFlex™ has more than 4 dosing channels (up to 6), the dual dosing channel option is utilized.
Up to 2 dual dosing channels are installed on the
NetaFlex™ 3G
, at the farthest manifold positions
(1 and 4).
The dual dosing channel option is applicable with 600 l/hr (158 GPH) or 50 l/hr (13 GPH) Venturis.
Dual dosing channels schematic diagram
CAUTION
There are fertilizer combinations that should never be used in
the dual dosing channel as they will induce crystalization and
cause clogging of the pipes.
Calcium Nitrate + Ammonium Sulfate => Calcium Sulfate
Calcium Nitrate + Potassium Sulfate => Calcium Sulfate
MKP + Calcium Nitrate => Calcium Phosphate
MAP + Calcium Nitrate => Calcium Phosphate
Phosphoric acid + Calcium Nitrate => Calcium Phosphate
In case of doubt regarding the use of any
combination of
fertilizers in the
dual dosing channel
, consult your local
Netafim™ representative.
scope of the
dual dosing channel
direction of flow
LEGEND
Electrical installation
CAUTION
Only qualified electricians are permitted to perform electrical installations!
Have a qualified electrician connect the NetaFlex™ 3G to the mains.
Follow the instructions in the enclosed Swichboard Documentation.

Other manuals for Netafim NETAFLEX 3G

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Netafim NETAFLEX 3G and is the answer not in the manual?

Netafim NETAFLEX 3G Specifications

General IconGeneral
BrandNetafim
ModelNETAFLEX 3G
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals