If the system-level diagnostics
tests…
Then…
Were completed without any
failures
There are no hardware problems and your storage system returns to
the prompt.
a.
Clear the status logs by entering the following command:
sldiag
device clearstatus
b. Verify that the log is cleared by entering the following command:
sldiag device status
The following default response is displayed:
SLDIAG: No log messages are present.
c.
Exit Maintenance mode by entering the following command:
halt
d. Enter the following command at the Loader prompt to boot the
storage system:
boot_ontap
You have completed system-level diagnostics.
Resulted in some test failures Determine the cause of the problem.
a.
Exit Maintenance mode by entering the following command:
halt
b. Perform a clean shutdown and disconnect the power supplies.
c. Verify that you observed all the requirements for running system-
level diagnostics, that cables are securely connected, and that
hardware components are properly installed in the storage
system.
d. Reconnect the power supplies and power on the storage system.
e. Repeat Steps 1 through 5 of Running slow system response
diagnostics.