• You must have installed the shelves, powered them on, and set the shelf IDs.
Install a drive shelf for a hot-add
Steps
1. If you are hot-adding one shelf using one set of RoCE capable ports (onboard RoCE capable ports) on
each controller module, and this is the only NS224 shelf in your HA pair, complete the following substeps.
Otherwise, go to the next step.
a. Cable shelf NSM A port e0a to controller A port e0c.
b. Cable shelf NSM A port e0b to controller B port e0d.
c. Cable shelf NSM B port e0a to controller B port e0c.
d. Cable shelf NSM B port e0b to controller A port e0d.
The following illustration shows cabling for one hot-added shelf using one set of RoCE capable ports
on each controller module:
2. If you are hot-adding one or two shelves using two sets of RoCE capable ports (on board and PCIe card
RoCE capable ports) on each controller module, complete the following substeps.