cluster1::> storage shelf show -shelf 2.5 -connectivity
Ê Shelf Name: 2.5
Ê Stack ID: 2
Ê Shelf ID: 5
Ê Shelf UID: 40:0a:09:70:02:2a:2b
Ê Serial Number: 101033373
Ê Module Type: IOM12
Ê Model: DS224C
Ê Shelf Vendor: NETAPP
Ê Disk Count: 24
Ê Connection Type: SAS
Ê Shelf State: Online
Ê Status: Normal
Paths:
Controller Initiator Initiator Side Switch Port Target Side
Switch Port Target Port TPGN
------------ --------- --------------------------
----------------------- ----------- ------
stor-8080-1 1a - -
- -
stor-8080-1 0d - -
- -
stor-8080-2 1a - -
- -
stor-8080-2 0d - -
- -
Errors:
------
-
7. If you disabled disk ownership automatic assignment in Step 1, manually assign disk ownership, and then
reenable disk ownership automatic assignment if needed:
a.
Display all unowned disks:
storage disk show -container-type unassigned
b.
Assign each disk:
storage disk assign -disk disk_name -owner owner_name
You can use the wildcard character to assign more than one disk at once.
c.
Reenable disk ownership automatic assignment if needed:
storage disk option modify -node
node_name -autoassign on
You need to reenable disk ownership automatic assignment on both controllers in an HA pair.
1558