If you see… Then…
Waiting for giveback… a. Log into the partner node.
b.
Confirm the target node is ready for giveback with the
storage
failover show
command.
7. Connect the console cable to the partner node.
8.
Give back the node using the
storage failover giveback -fromnode local command.
9.
At the cluster prompt, check the logical interfaces with the
net int -is-home false command.
If any interfaces are listed as "false", revert those interfaces back to their home port using the
net int
revert
command.
10.
Move the console cable to the repaired node and run the
version -v command to check the ONTAP
versions.
11.
Restore automatic giveback if you disabled it by using the
storage failover modify -node local
-auto-giveback true
command.
Restore OKM, NSE, and NVE as needed - AFF C190
Once environment variables are checked, you must complete steps specific to systems
that have Onboard Key Manager (OKM), NetApp Storage Encryption (NSE) or NetApp
Volume Encryption (NVE) enabled.
1. Determine which section you should use to restore your OKM, NSE, or NVE configurations: If NSE or NVE
are enabled along with Onboard Key Manager you must restore settings you captured at the beginning of
this procedure.
â—¦ If NSE or NVE are enabled and Onboard Key Manager is enabled, go to
Restore NVE or NSE when
Onboard Key Manager is enabled
.
â—¦ If NSE or NVE are enabled for ONTAP 9.6, go to
Restore NSE/NVE on systems running ONTAP 9.6
and later
.
Restore NVE or NSE when Onboard Key Manager is enabled
Steps
1. Connect the console cable to the target node.
2.
Use the
boot_ontap command at the LOADER prompt to boot the node.
3. Check the console output:
If the console displays… Then…
The LOADER prompt
Boot the node to the boot menu: boot_ontap menu
965