40
PreCharge Circuit Fault
Pre-charge of internal line capacitors is too fast or capacitors
voltage is fixed to zero during precharge.
Blocking
41
PreCharge Failed
Pre-charge phase fails to charge capacitors till the voltage level of
key input.
Blocking
42
Main Contactor Welded
Before closing the line contactor, internal capacitors are loaded
for short time and voltage doesn't go down.
Blocking
43
Main Contactor Did Not
Close
The difference between key switch and capacitors voltage is too
high after the contactor has been powered.
Blocking
44
Interlock Disabled
Interlock input is not active and line contactor is open.
Stopping
45
Static Return to Off
Traction
One or more traction inputs are active at the key on, after an
Emergency stop or a controlled stop procedure.
Warning
46
Static Return to Off
Hydraulic
One or more hydraulic/pump inputs are active at the key on after a
controlled stop procedure.
Warning
47
Traction Throttle Fault
A fault condition of traction throttle is detected.
Stopping
48
Hydraulic Throttle Fault
A fault condition of hydraulic/pump throttle is detected.
Stopping
49
Brake Throttle Fault
A fault condition of brake throttle is detected.
Stopping
50
Service Time Expired
Service Timer has expired.
Warning
51
Low Battery State of
Charge
Battery state of charge estimated is lower than minimum value
defined by the user via related parameter.
Limiting
52
Wrong Parameter
Parameter setting is out of the permitted range.
Blocking
53
Restart Required
Changed a parameter setting.
Blocking
54
Can Bus Off
Bus Off condition detected.
Stopping
55
Can Open Circuit
Messages no longer received.
Stopping
56
Can Bad Wiring or Short
Circuit
Can bus synchronization phase failed or bus off condition
detected.
Blocking
57
Not Assigned
-
-
58
Not Assigned
-
-
59
Not Assigned
-
-
60
Not Assigned
-
-
61
Not Assigned
-
-
62
Net Timeout Heartbeat
At least one Heartbeat hasn't been received during the startup of
the network or after the synchronization phase.
Stopping
63
Net RPDO Timeout
At least one PDO hasn't been received.
Stopping
64
Main Contactor Close
Command Timeout
Pre-charge timer has expired before the master sends the power
ready request.
Blocking

Questions and Answers: