Monitor, Maintain, and Optimize
121
ReadyNAS for Home RAIDiator 4.2
To configure remote UPS low battery shutdown:
1. Ensure that the remote ReadyNAS system is configured to allow remote UPS
monitoring:
a. On the remote ReadyNAS system, select System > Power from the FrontView main
menu.
b. Scroll down to the UPS Configuration pane.
c. Click the Enable network sharing of attached UPS check box.
d. Choose an access restriction option, as follows:
• Leave the Hosts allowed access field blank to allow any system on you LAN to
share this UPS.
• Enter the IP address of the local ReadyNAS system in the Hosts allowed access
field to restrict sharing of this UPS to only that ReadyNAS system.
e. Click the Apply button.
2. On your local ReadyNAS system, select System > Power from the FrontView main menu.
The Power screen displays.
3. Scroll down to the UPS Configuration pane.
4. (Optional) Select the Enable monitoring of UPS physically attached to a remote
ReadyNAS check box and enter the IP address of the remote ReadyNAS system in the
Remote IP address field.
5. (Optional) Select the Monitor UPS over SNMP check box, enter the SNMP UPS address,
and choose an option from the Use MIB drop-down list.
For more information about MIB settings, see the documentation that accompanied your
SNMP UPS.
6. Click the Apply button.
Your settings are saved.